Vimar Idea – Residual Current Breaker with Overcurrent Protection – 1 Pole+N – 6A – 10mA – Grey – 2 Module (RCBO) (16511.06)

$480.00

Vimar Idea - Residual Current Breaker with Overcurrent Protection - 1 Pole+N - Supply Voltage 120-230 V~50-60Hz
  Our Website DOES NOT ACCEPT PAYMENTS. Please complete your enquiry and checkout. We will send you a quote with AVAILABILITY, PRICE & FREIGHT (if required)
or Call Now 0755 292 544

Vimar Idea - Residual Current Breaker with Over current Protection (RCBO) (16511.06)

1 Pole+N - Grey - 2 Module

6A - 10mA - Breaking Capacity 1500A

Supply Voltage 120-230 V~50-60Hz

16511.06 – Suits Idea / Devices / Residual current breakers (RCBOs)

1P+N C6 RCBO 120-230V 10mA grey
1P+N C 6 residual current breaker with overcurrent protection, supply voltage 120-230 V~ 50-60 Hz, IΔn 10 mA, breaking capacity 1500 A, grey - 2 modules

Devices suitable to be installed at the end of a system for the protection of the load connected after them directly or through a socket outlet, against overload and short-circuit, and for the protection of the user against electrocution. The protection against overload and against short-circuit is granted by the electromagnetic part of the equipment; the protection of the user against electrocution is given by the residual current breaker with overcurrent protection, for a value of 10 mA (sensitivity).

A green LED on the front indicates normal operation, i.e. mains voltage present and contacts closed. The residual current function is also tripped by non-sinusoidal fault currents (alternating currents with unidirectional pulsating currents).

They are particularly suitable for the protection of:

  • appliances at the end of the line in locations with high risk of electrocution (bathrooms, shower-baths, etc.)
  • socket outlets for the supply of class I appliances with electronic circuits
  • socket outlets for the supply of portable appliances in residential and similar applications (electric irons, electrical tools, etc.)

3 Module Composition Shown in Diagram

Downloads:

  • supply voltage: 120-230 V~ 50-60 Hz
  • residual current (sensitivity): IΔn 10 mA
  • operation depending on the mains voltage: to be connected after a master RCBO
  • rated current: 6 A
  • two-pole section with 1 protected pole
  • residual making and breaking capacity: 1500 A
  • C type thermal-magnetic action (see current-time tripping diagram)
  • A type equipment for alternating and unidirectional pulsating fault currents

3 Module Composition Shown in Diagram

Weight 0.1 kg
Dimensions 6.0 × 5.0 × 5.0 cm